search
We are your powerful partner in sensor technology for the automotive, commercial-vehicle and conventional industries. When you work with us, you can rely on intelligent solutions for measuring pressure and temperature as well as for combined sensors.
i2s – Intelligente Sensorsysteme Dresden GmbH
As part of the Amphenol Corporation, we are represented worldwide.
We have summarised our most important milestones for you.
We offer you an extensive product portfolio. In addition, we develop and manufacture customised sensors for your specific application.
From sensors for air-conditioning systems to oil pressure – we offer you intelligent solutions for battery and hydrogen propulsion as well as for internal-combustion engines.
Commercial vehicles are equipment for the working world – we equip your commercial vehicles with first-class sensor technology.
We have developed pressure sensors specifically for use in hydrogen environments, for air-conditioning solutions and process control, and for stationary energy generation by fuel cells.
The modular design of our sensors makes it possible to create an individual solution for your specific application! Why? Because we design and manufacture customised sensors. Whether it’s modifications to a mechanical or electronic design or a new, customised development – we implement your requirements quickly and cost-effectively.
Our climate-pressure sensors are installed in air-conditioning systems for temperature regulation.
Our combined pressure and temperature sensors are used to measure the oil pressure in the transmission.
Our intelligent sensor systems are also used in motorsports.
Our combined pressure and temperature sensors for low and high pressure are used in e-mobility.
Hydrogen propulsion is the future for environmentally friendly commercial vehicles and buses.
Whether it’s pressure, temperature or both in a single sensor: i2s develops and manufactures sensor technology that is used on a daily basis in the automotive sector, commercial vehicles, mechanical engineering, measurement and testing technology, industry and, increasingly, in data centre. With over 20 years’ experience, we bring our expertise directly to your project – from established series products to new, tailor-made developments.
Modern data centers must process enormous amounts of data. Cloud applications, artificial intelligence, high-performance computing, and data-intensive business processes require powerful processors, graphics processing units, and storage systems. However, as computing power increases, so does the amount of heat generated inside the servers. This heat must be reliably dissipated so that the technical components can operate within their specified temperature ranges.
This is precisely where thermal management comes into play. Thermal management encompasses all technical measures used to absorb, transport, regulate, and dissipate heat within a data center. These include traditional air cooling as well as modern liquid cooling, heat pumps, heat exchangers, pumps, coolant circuits, and the associated sensor technology. Temperature and pressure sensors from i2s can provide important measurement data for these systems, thereby supporting reliable monitoring and demand-based control of the cooling process.
Get in touch with us!
Have questions or want to find out more about our products? Then write to us – we will be happy to assist you!
CONTACT
For Thermal Management in Data Centers
The CCT pressure-temperature sensor measures pressure and temperature simultaneously and is used in thermal management applications in data centers—particularly in refrigeration systems, heat pumps, and cooling circuits for waste heat recovery. Its specialized design ensures high measurement accuracy and a fast response time in flowing media.
Find out more
For liquid cooling circuits in server racks
The Data Center Coolant Pressure Sensor (DCP) is designed for installation in the liquid cooling circuit of data center racks and monitors the coolant pressure at the racks' inlet and outlet to assess cooling performance and protect the server blades.
find out more
For Data Centers
The Climate Control Pressure Transmitter (CCT) was specifically designed to measure the pressure of refrigerants in refrigeration systems and heat pumps. Its lightweight and rugged aluminum housing makes this sensor an ideal solution for thermal management in data centers.
For harsh operating conditions
The IPS pressure sensor is used in industrial applications and data centers where high standards of ruggedness and media compatibility are required. Even under harsh operating conditions, rough handling, and high levels of vibration, the IPS proves to be a reliable partner, delivering precise and stable measurement data throughout its entire lifecycle.
For industry applications and HVCAR
The VSP pressure sensor is available in a full stainless- steel design for universal use in general industrial applications. Its robust, all-welded stainless-steel construction makes it a reliable solution wherever broad media compatibility and resistance to harsh operating conditions are required.
Thermal management describes the entire path of heat, from its generation to its dissipation into the environment or its reuse.
Heat is generated primarily in electronic components such as:
This heat must first be absorbed by the individual components. It is then transported away from the server via air or liquid. From there, it travels through server racks, cooling circuits, and heat exchangers before finally reaching the data center’s central cooling system.
Electronic components operate reliably only within certain temperature ranges. If a processor gets too hot, it may automatically reduce its performance. This process is often referred to as thermal throttling. If the temperature continues to rise, protective mechanisms may shut down individual components or entire systems. Persistently high temperatures can also accelerate the aging of electronic components.
Effective thermal management therefore serves several purposes:
As power density increases in modern data centers, this task becomes more challenging. Artificial intelligence servers, in particular, contain high-performance GPUs and accelerators that can generate large amounts of heat in a small space. As a result, liquid cooling systems are increasingly being used alongside traditional air cooling.
The basic principle is simple: Heat is absorbed at one location and then transported to another.
A typical heat path might look like this, for example:
In practice, multiple cooling circuits can be interconnected. Especially in large data centers, this results in a complex interplay of pumps, valves, heat exchangers, cooling units, and sensors. To ensure this system operates reliably, key operating parameters must be continuously monitored.
In a liquid cooling system, the coolant must be reliably transported through pipes, heat exchangers, and heat sinks. Pumps generate the necessary pressure for this. At the same time, pipes, filters, valves, and cold plates create flow resistance.
Pressure sensors can help monitor these operating conditions.
For example, they can be used to:
Since pipes, connections, heat exchangers, and seals are designed for specific pressure ranges, pressure monitoring is an essential part of safe system operation.
A sensor in a cooling system must provide reliable readings over a long period of time. It may be in constant contact with coolants and exposed to fluctuating temperatures and pressures. Therefore, several factors are important when selecting a sensor.
Media CompatibilityAll parts of the sensor that come into contact with the cooling medium must be compatible with that medium. Relevant examples include water, deionized water, water-glycol mixtures, and refrigerants used in heat pump and refrigeration systems. Not only the fluid itself, but also its concentration, temperature, and pressure influence the choice of materials.
Fast Response TimeTemperatures within a cooling system can change dynamically. As server load increases, heat generation can also rise rapidly. Fast temperature measurement enables the control system to detect changes in a timely manner.
AccuracyThe required accuracy depends on the specific application. A different level of accuracy may be sufficient for simple monitoring than for precise control. It is important that the sensor delivers stable readings across the entire intended operating range.
Long-Term StabilityData centers operate around the clock. Sensors should therefore provide reliable and reproducible readings even over long periods of operation. High long-term stability also makes it easier to detect long-term changes.
Compact DesignSpace is often limited inside server racks, CDUs, and coolant distributors. Compact sensors are easier to integrate into existing systems.
Electrical InterfacesThe measured values must be transmitted to a control system. Depending on the application, different signals and interfaces may be required. Electrical connections and connectors can also be critical for integration.
A modern cooling system should, as much as possible, provide only as much capacity as is actually needed. If pumps, fans, and refrigeration systems operate continuously at maximum capacity, energy may be wasted. On the other hand, reducing cooling capacity too much can lead to elevated temperatures. Sensors provide the foundation for controlled operation.
Based on the measured values, control systems can, for example:
The sensor itself does not control these components. However, it provides the information required for intelligent control.
Cooling is one of the major sources of energy consumption in a data center. Therefore, a key goal of thermal management is to provide the necessary cooling capacity as efficiently as possible. Pressure and temperature measurements can help provide a better understanding of the actual operating conditions. Instead of operating with large safety margins, a system can be controlled based on real-time measurements. Sensors do not directly save energy, but they do enable more precise control of the systems.
Heat pumps can be used in heat management to transfer heat specifically between different temperature levels. To do this, they utilize a refrigerant cycle in which pressure and temperature are closely related. For efficient and reliable operation, these operating parameters must therefore be continuously monitored.
Pressure and temperature sensors provide important measurement data for controlling the refrigerant circuit and can be used, for example, to monitor compressors, evaporators, and condensers. With its CCT pressure/temperature sensors, i2s offers combined sensor solutions for heat pump applications. Our pressure/temperature sensors are also available in a stainless steel version, which ensures reliable long-term operation even when used with corrosive media.
Thermal management encompasses all measures used to capture, transport, and dissipate the heat generated by servers. These include air cooling, liquid cooling, pumps, heat exchangers, cooling distribution units, sensors, and control systems.
Servers generate heat during operation. If this heat is not adequately dissipated, processors may reduce their performance or systems may shut down. Controlled cooling ensures reliable operation.
Depending on the system, sensors are used to measure temperature, pressure, differential pressure, flow, humidity, level, or leaks. i2s focuses in particular on pressure and temperature sensors, as well as combined sensor solutions.
Temperature sensors monitor, for example, the supply and return temperatures. This makes it possible to determine how much the cooling medium is heating up and whether the cooling system is functioning as intended.
Pressure sensors monitor the operating pressure within a cooling circuit. Changes in pressure may indicate problems with pumps, valves, blocked lines, or other changes in the system.
Possible measurement points include cooling distribution units, pumps, heat exchangers, coolant distributors, rack supply lines, and the supply and return lines of a liquid cooling system.
The flow temperature indicates the temperature of the coolant before heat is absorbed. The return temperature indicates the temperature afterwards. The difference between these two values provides information about the heat absorption of the system.
Cooling primarily refers to the actual process of heat dissipation. Thermal management takes into account the entire system, including sensors, control systems, heat distribution and optimisation.
Liquid cooling uses a liquid to transfer heat. This allows heat to be absorbed closer to high-performance processors and GPUs. The method is of particular interest for servers with high power density.
Yes. Combined pressure and temperature sensors measure both values at the same measurement point.
Sensors do not reduce energy consumption directly. However, the data they provide enables pumps, fans, valves and refrigeration systems to be controlled in line with actual demand.
Have questions or want to find out more about our products?Then write to us – we will be happy to assist you!